ISO 8100-7:2024 standard totals 25 pages and comprehensively covers the usage needs of various persons with disabilities, including visual impairments, hearing impairments, physical impairments, and cognitive impairments. Key technical requirements include:

1) Minimum internal elevator car dimensions of 1100mm × 1400mm to accommodate wheelchair users;

2) Minimum net elevator door opening width of 900mm;

3) Mandatory braille floor buttons and voice announcement systems;

4) Elevator landing leveling accuracy not exceeding ±10mm;

5) Three-sided handrails must be installed inside the car;

6) Adjustable door dwell time, with a minimum of 20 seconds;

7) Emergency call systems must have both voice and visual feedback functions.


The standard also provides guidance suggestions for enhanced accessibility in the appendix, helping designers and manufacturers create more inclusive vertical transportation environments.