Electrical match
Confirm AC-15 or DC-13 duty, operating voltage, current, contact state, terminal layout and safety-controller requirements.
Insulation voltage:380V Rated current:AC2A,DC0.3A Rated Voltage:AC220V,DC110V Temperature:-5℃~+40℃ IP class:IP20 Breaking capacity:1000A
Roller-actuated limit switch with a spring-loaded mechanical linkage and covered screw terminals. Confirm the complete label, contact state, operating direction and mounting dimensions before replacement.
Four reviewed photographs show the same S3-B1370 structure from distinct views: complete roller-and-lever assembly, readable side label, covered contact terminals and opposite side profile. The original markings are retained for electrical and model verification.




| Item | Reviewed reference | Order check |
|---|---|---|
| Model | S3-B1370 | Confirm the complete physical label and wide-body version |
| Product type | Roller-actuated elevator limit switch | Confirm the intended limit or safety-circuit position |
| Standard marking | GB 14048.5 | Confirm project and local acceptance requirements |
| AC utilization rating shown | AC-15: 220 V / 2 A | Confirm the actual load category and circuit duty |
| DC utilization rating shown | DC-13: 110 V / 0.3 A | Confirm voltage, load and switching frequency |
| Insulation reference conflict | Physical label: Ui/Ith 500 V; backend record: insulation voltage 380 V | Obtain the supplied revision datasheet before final selection |
| Backend environmental reference | −5 to +40 °C; IP20 | Confirm against the actual unit and installation environment |
| Backend breaking-capacity reference | 1000 A | Do not apply until confirmed by exact-model documentation |
| Mechanical interface | Large roller, lever linkage, return spring and covered screw terminals | Compare wheel diameter, lever travel, mounting and terminal access |
The 500 V marking on the photographed unit does not match the 380 V backend entry. This conflict is intentionally retained for confirmation rather than resolved by assumption.
Confirm AC-15 or DC-13 duty, operating voltage, current, contact state, terminal layout and safety-controller requirements.
Check roller diameter, lever direction and travel, spring return, operating force and available clearance.
Compare body width, mounting holes, terminal-cover access, ambient temperature and required ingress protection.
No. Confirm the wide-body housing, roller and lever geometry, mounting points, contacts and full label.
The supplied photograph shows 500 V while the backend record says 380 V. Obtain an exact-revision datasheet or supplier confirmation before selection.
Provide the old unit's full label, installed position, contact state, circuit duty, body and mounting dimensions, and roller travel.
Des options d’emballage protecteur sélectionnées en fonction de la taille, du poids et des exigences d’expédition des produits.
De la fabrication de précision à l’inspection finale, chaque étape contribue à assurer une qualité constante et un approvisionnement fiable.
Un approvisionnement fiable en pièces d’ascenseur, avec un service direct usine, une qualité authentique et un support inébranlable.
Nous assurons un service d’expédition fiable pour les commandes de pièces d’ascenseur dans le monde entier, vous permettant de recevoir les bons produits de manière efficace et en toute confiance.
Des options de livraison flexibles pour les clients sur tous les marchés internationaux.
Les modes d’expédition peuvent être adaptés à votre destination, à votre calendrier et aux spécificités de votre commande.
Les produits sont emballés de manière sécurisée afin de les protéger durant le transport.
Notre équipe assure la coordination de la livraison, depuis la confirmation de la commande jusqu’au service après-vente.
Nous fournissons les certificats, rapports d’inspection et documents de conformité applicables aux pièces d’ascenseur, afin de vous aider à vous approvisionner en toute confiance.
Choose a sales representative to discuss your project.
Loading contacts…