ISO/TR 8101-10:2024 totals 68 pages and compares elevator fire safety standards in 15 countries and regions, including ISO, EU, USA, Canada, Australia, Japan, and China. The report focuses on analyzing:

1) Design and usage requirements for firefighters' lifts;

2) Elevator operation modes in case of fire;

3) Conditions and requirements for using elevators for personnel evacuation;

4) Fire protection requirements for elevator shafts and machine rooms;

5) Elevator fire alarm and linkage control systems.


The report points out that there are significant differences in global elevator fire safety standards, which bring inconvenience to international trade and cross-border projects. It recommends that countries refer to international standards when formulating and revising elevator fire safety standards and gradually achieve global unification.