| Item | Submitted value | Buyer check |
|---|---|---|
| Model / configuration | BOSH-D25 / 1P single cooling | Confirm complete physical nameplate |
| Cooling / input | 2500 W ±10% / ≤1000 W | Confirm stated operating conditions |
| Power supply | 220–240 V AC, 50 Hz; 187–242 V input range | Verify site supply and protection |
| Airflow | ≥400 m³/h, indoor side | Confirm openings and duct resistance |
| Dimensions / weight | 455 × 345 × 605 mm; 29/32 kg net/gross | Check roof layout and structure |
| Protection | IP24, Class I; temperature/current overload protection | Confirm actual unit and installation environment |
| Refrigerant | R22 in the submitted sheet | Confirm current supplied unit and destination rules |
An independent trade-data result also identifies BOSH-D25 as a 1P, 2.5 kW, 220 V elevator air conditioner. The more detailed values above come from the submitted BOSH-D25 sheet and still require nameplate confirmation.

The submitted reference shows flexible ducts, transition pieces, rails, ties and small installation components. Treat it as a scope-checking reference only; the quotation should list every included item separately.
Send the complete model and electrical nameplate, refrigerant type/charge and production revision.
Confirm space, support, return/outlet openings, duct sizes and direction, service access and condensate treatment.
List the main unit, controller/remote, ducts, transitions, rails, brackets, clamps, fasteners and documents.
Yes, based on the reviewed BOSH-D25 sheet. Confirm the physical unit before supply.
Not automatically. Require a line-by-line scope confirmation in the quotation.
Check fixation, electrical protection and grounding, duct sealing, airflow, noise/vibration, service access and car-top safety clearances.
Yes. Confirm the actual unit and applicable destination refrigerant rules before purchase or shipment.
根据产品尺寸、重量及运输需求,精选各类防护性包装方案。
从精密加工到最终检验,每一道工序都致力于保障产品质量稳定、供应可靠。
工厂直供、品质保证、售后无忧,为您提供可靠的电梯零部件供应服务。
我们为全球范围内的电梯零部件订单提供可靠的运输支持,助您高效、安心地收到所需产品。
为遍布全球市场的客户提供灵活多样的配送方案。
可根据您的目的地、交货时间及订单需求,安排合适的运输方式。
产品经过安全包装,有效保护运输过程中的完好无损。
从订单确认到售后服务,我们的团队全程协助协调配送。
我们提供齐全的电梯零部件相关证书、检测报告及合规文件,让您采购更放心。
Choose a sales representative to discuss your project.
Loading contacts…