Compact elevator-cabin climate control with cooling-only and cooling/heating configurations. Select the capacity and operating mode for the cabin, then match the duct arrangement and mounting space.

| Item | Specification |
|---|---|
| Main model | CAC-YKTD25-1P |
| Main configuration | 1 P, cooling only |
| Rated cooling capacity | 2500 W |
| Cooling input power | 930 W |
| Air circulation | 380 m³/h |
| Rated supply | 220 V / 50 Hz |
| Cabin noise specification | ≤49 dB |
| Ingress protection / insulation class | IPX4 / Class I |
| Main-unit dimensions | 580 × 450 × 350 mm |
| Net unit mass | 35 kg |
| Condensate management | Integrated condensate evaporation design |
| Idle operation | Energy-saving mode coordinated with elevator idle signals |
| Parameter | CAC-YKTD25-1P | CAC-YKD32-1.5P | CAC-YKL25-1P | CAC-YKL32-1.5P |
|---|---|---|---|---|
| Operating mode | Cooling only | Cooling only | Cooling / heating | Cooling / heating |
| Nominal capacity class | 1 P | 1.5 P | 1 P | 1.5 P |
| Rated cooling capacity | 2500 W | 3200 W | 2500 W | 3200 W |
| Auxiliary heating capacity | Not applicable | Not applicable | 2200 W | 2300 W |
| Cooling input power | 930 W | 1310 W | 930 W | 1310 W |
| Heating input power | Not applicable | Not applicable | 2300 W | 3100 W |
| Air circulation | 380 m³/h | 430 m³/h | 380 m³/h | 550 m³/h |
| Cabin noise specification | ≤49 dB | ≤50 dB | ≤50 dB | ≤52 dB |
| Rated supply | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz |
| Protection / insulation | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I |
| Main-unit dimensions | 580 × 450 × 350 mm | 580 × 450 × 350 mm | 580 × 450 × 350 mm | 600 × 620 × 380 mm |
| Net unit mass | 35 kg | 38 kg | 35 kg | 42 kg |
CAC-YKL25-1P and CAC-YKL32-1.5P provide cooling and heating. CAC-YKTD25-1P and CAC-YKD32-1.5P are cooling-only configurations.
No. The first three configurations use a 580 × 450 × 350 mm unit envelope; CAC-YKL32-1.5P uses 600 × 620 × 380 mm. Check mounting and duct clearances separately.
The series uses an integrated condensate-evaporation design. Arrange installation, maintenance access and condensate handling to suit the selected unit and operating conditions.
Confirm the cabin cooling load, heating requirement, available mounting space, air-duct arrangement, power supply and elevator control interface.
根据产品尺寸、重量及运输需求,精选各类防护性包装方案。
从精密加工到最终检验,每一道工序都致力于保障产品质量稳定、供应可靠。
工厂直供、品质保证、售后无忧,为您提供可靠的电梯零部件供应服务。
我们为全球范围内的电梯零部件订单提供可靠的运输支持,助您高效、安心地收到所需产品。
为遍布全球市场的客户提供灵活多样的配送方案。
可根据您的目的地、交货时间及订单需求,安排合适的运输方式。
产品经过安全包装,有效保护运输过程中的完好无损。
从订单确认到售后服务,我们的团队全程协助协调配送。
我们提供齐全的电梯零部件相关证书、检测报告及合规文件,让您采购更放心。
Choose a sales representative to discuss your project.
Loading contacts…