Electrical match
Confirm AC-15 or DC-13 duty, operating voltage, current, contact state, terminal layout and safety-controller requirements.
Insulation voltage:380V Rated current:AC2A,DC0.3A Rated Voltage:AC220V,DC110V Temperature:-5℃~+40℃ IP class:IP20 Breaking capacity:1000A
Roller-actuated limit switch with a spring-loaded mechanical linkage and covered screw terminals. Confirm the complete label, contact state, operating direction and mounting dimensions before replacement.
Four reviewed photographs show the same S3-B1370 structure from distinct views: complete roller-and-lever assembly, readable side label, covered contact terminals and opposite side profile. The original markings are retained for electrical and model verification.




| Item | Reviewed reference | Order check |
|---|---|---|
| Model | S3-B1370 | Confirm the complete physical label and wide-body version |
| Product type | Roller-actuated elevator limit switch | Confirm the intended limit or safety-circuit position |
| Standard marking | GB 14048.5 | Confirm project and local acceptance requirements |
| AC utilization rating shown | AC-15: 220 V / 2 A | Confirm the actual load category and circuit duty |
| DC utilization rating shown | DC-13: 110 V / 0.3 A | Confirm voltage, load and switching frequency |
| Insulation reference conflict | Physical label: Ui/Ith 500 V; backend record: insulation voltage 380 V | Obtain the supplied revision datasheet before final selection |
| Backend environmental reference | −5 to +40 °C; IP20 | Confirm against the actual unit and installation environment |
| Backend breaking-capacity reference | 1000 A | Do not apply until confirmed by exact-model documentation |
| Mechanical interface | Large roller, lever linkage, return spring and covered screw terminals | Compare wheel diameter, lever travel, mounting and terminal access |
The 500 V marking on the photographed unit does not match the 380 V backend entry. This conflict is intentionally retained for confirmation rather than resolved by assumption.
Confirm AC-15 or DC-13 duty, operating voltage, current, contact state, terminal layout and safety-controller requirements.
Check roller diameter, lever direction and travel, spring return, operating force and available clearance.
Compare body width, mounting holes, terminal-cover access, ambient temperature and required ingress protection.
No. Confirm the wide-body housing, roller and lever geometry, mounting points, contacts and full label.
The supplied photograph shows 500 V while the backend record says 380 V. Obtain an exact-revision datasheet or supplier confirmation before selection.
Provide the old unit's full label, installed position, contact state, circuit duty, body and mounting dimensions, and roller travel.
Các lựa chọn đóng gói bảo vệ được lựa chọn phù hợp với kích thước, trọng lượng sản phẩm và yêu cầu vận chuyển.
Từ gia công chính xác đến kiểm tra cuối cùng, mọi quy trình đều hướng tới chất lượng đồng nhất và nguồn cung ổn định.
Nguồn cung phụ tùng thang máy đáng tin cậy với dịch vụ trực tiếp từ nhà máy, chất lượng chính hãng và hỗ trợ tận tâm.
Chúng tôi cung cấp dịch vụ vận chuyển đáng tin cậy cho các đơn hàng phụ tùng thang máy trên toàn thế giới, giúp bạn nhận được đúng sản phẩm một cách nhanh chóng và an tâm.
Các phương thức giao hàng linh hoạt dành cho khách hàng trên khắp thị trường thế giới.
Các hình thức vận chuyển có thể được bố trí phù hợp với điểm đến, lịch trình và yêu cầu của đơn hàng.
Sản phẩm được đóng gói chắc chắn nhằm bảo vệ trong quá trình vận chuyển.
Đội ngũ của chúng tôi hỗ trợ điều phối giao hàng từ khi xác nhận đơn hàng đến dịch vụ hậu mãi.
Chúng tôi cung cấp các chứng chỉ, báo cáo kiểm định và tài liệu tuân thủ liên quan đến phụ tùng thang máy, giúp bạn yên tâm hơn khi mua sắm.
Choose a sales representative to discuss your project.