Compact elevator-cabin climate control with cooling-only and cooling/heating configurations. Select the capacity and operating mode for the cabin, then match the duct arrangement and mounting space.

| Item | Specification |
|---|---|
| Main model | CAC-YKTD25-1P |
| Main configuration | 1 P, cooling only |
| Rated cooling capacity | 2500 W |
| Cooling input power | 930 W |
| Air circulation | 380 m³/h |
| Rated supply | 220 V / 50 Hz |
| Cabin noise specification | ≤49 dB |
| Ingress protection / insulation class | IPX4 / Class I |
| Main-unit dimensions | 580 × 450 × 350 mm |
| Net unit mass | 35 kg |
| Condensate management | Integrated condensate evaporation design |
| Idle operation | Energy-saving mode coordinated with elevator idle signals |
| Parameter | CAC-YKTD25-1P | CAC-YKD32-1.5P | CAC-YKL25-1P | CAC-YKL32-1.5P |
|---|---|---|---|---|
| Operating mode | Cooling only | Cooling only | Cooling / heating | Cooling / heating |
| Nominal capacity class | 1 P | 1.5 P | 1 P | 1.5 P |
| Rated cooling capacity | 2500 W | 3200 W | 2500 W | 3200 W |
| Auxiliary heating capacity | Not applicable | Not applicable | 2200 W | 2300 W |
| Cooling input power | 930 W | 1310 W | 930 W | 1310 W |
| Heating input power | Not applicable | Not applicable | 2300 W | 3100 W |
| Air circulation | 380 m³/h | 430 m³/h | 380 m³/h | 550 m³/h |
| Cabin noise specification | ≤49 dB | ≤50 dB | ≤50 dB | ≤52 dB |
| Rated supply | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz |
| Protection / insulation | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I |
| Main-unit dimensions | 580 × 450 × 350 mm | 580 × 450 × 350 mm | 580 × 450 × 350 mm | 600 × 620 × 380 mm |
| Net unit mass | 35 kg | 38 kg | 35 kg | 42 kg |
CAC-YKL25-1P and CAC-YKL32-1.5P provide cooling and heating. CAC-YKTD25-1P and CAC-YKD32-1.5P are cooling-only configurations.
No. The first three configurations use a 580 × 450 × 350 mm unit envelope; CAC-YKL32-1.5P uses 600 × 620 × 380 mm. Check mounting and duct clearances separately.
The series uses an integrated condensate-evaporation design. Arrange installation, maintenance access and condensate handling to suit the selected unit and operating conditions.
Confirm the cabin cooling load, heating requirement, available mounting space, air-duct arrangement, power supply and elevator control interface.
제품의 크기, 무게 및 배송 요구사항에 따라 선택된 보호 포장 옵션입니다.
정밀한 제조부터 최종 검사까지, 모든 공정이 일관된 품질과 신뢰할 수 있는 공급을 뒷받침합니다.
공장 직영 서비스, 정품 품질, 믿을 수 있는 지원으로 안정적인 엘리베이터 부품 공급을 제공합니다.
전 세계적으로 엘리베이터 부품 주문에 대한 신뢰할 수 있는 배송 서비스를 제공하여, 적합한 제품을 효율적이고 안심하며 받아보실 수 있도록 지원합니다.
글로벌 시장 전역의 고객을 위한 유연한 배송 옵션을 제공합니다.
배송 방법은 목적지, 일정 및 주문 요구사항에 따라 조정 가능합니다.
운송 중 제품을 안전하게 보호하기 위해 신중히 포장됩니다.
당사 팀이 주문 확인부터 사후 서비스까지 배송 일정을 철저히 관리합니다.
엘리베이터 부품에 대한 관련 인증서, 검사 보고서 및 규정 준수 문서를 제공하여 더욱 신뢰감 있게 소싱하실 수 있도록 지원합니다.
Choose a sales representative to discuss your project.