1P COLD
Compact elevator-cabin climate control with cooling-only and cooling/heating configurations. Select the capacity and operating mode for the cabin, then match the duct arrangement and mounting space.

| Item | Specification |
|---|---|
| Main model | CAC-YKTD25-1P |
| Main configuration | 1 P, cooling only |
| Rated cooling capacity | 2500 W |
| Cooling input power | 930 W |
| Air circulation | 380 m³/h |
| Rated supply | 220 V / 50 Hz |
| Cabin noise specification | ≤49 dB |
| Ingress protection / insulation class | IPX4 / Class I |
| Main-unit dimensions | 580 × 450 × 350 mm |
| Net unit mass | 35 kg |
| Condensate management | Integrated condensate evaporation design |
| Idle operation | Energy-saving mode coordinated with elevator idle signals |
| Parameter | CAC-YKTD25-1P | CAC-YKD32-1.5P | CAC-YKL25-1P | CAC-YKL32-1.5P |
|---|---|---|---|---|
| Operating mode | Cooling only | Cooling only | Cooling / heating | Cooling / heating |
| Nominal capacity class | 1 P | 1.5 P | 1 P | 1.5 P |
| Rated cooling capacity | 2500 W | 3200 W | 2500 W | 3200 W |
| Auxiliary heating capacity | Not applicable | Not applicable | 2200 W | 2300 W |
| Cooling input power | 930 W | 1310 W | 930 W | 1310 W |
| Heating input power | Not applicable | Not applicable | 2300 W | 3100 W |
| Air circulation | 380 m³/h | 430 m³/h | 380 m³/h | 550 m³/h |
| Cabin noise specification | ≤49 dB | ≤50 dB | ≤50 dB | ≤52 dB |
| Rated supply | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz | 220 V / 50 Hz |
| Protection / insulation | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I | IPX4 / Class I |
| Main-unit dimensions | 580 × 450 × 350 mm | 580 × 450 × 350 mm | 580 × 450 × 350 mm | 600 × 620 × 380 mm |
| Net unit mass | 35 kg | 38 kg | 35 kg | 42 kg |
CAC-YKL25-1P and CAC-YKL32-1.5P provide cooling and heating. CAC-YKTD25-1P and CAC-YKD32-1.5P are cooling-only configurations.
No. The first three configurations use a 580 × 450 × 350 mm unit envelope; CAC-YKL32-1.5P uses 600 × 620 × 380 mm. Check mounting and duct clearances separately.
The series uses an integrated condensate-evaporation design. Arrange installation, maintenance access and condensate handling to suit the selected unit and operating conditions.
Confirm the cabin cooling load, heating requirement, available mounting space, air-duct arrangement, power supply and elevator control interface.
إمداد موثوق بقطع غيار المصاعد مع خدمة مباشرة من المصنع، وجودة أصلية ودعم يعتمد عليه.
Choose a sales representative to discuss your project.
Loading contacts…