15KW/18.5KW
A V1000 variable-frequency drive with heavy-duty and normal-duty ratings. Select the duty rating to match the motor and operating cycle.

| Duty | Motor rating | Rated output current | Overload capability | Rated input current |
|---|---|---|---|---|
| Heavy duty (HD) | 15 kW | 31 A | 150% for 60 s | Approximately 39 A |
| Normal duty (ND) | 18.5 kW | 38 A | 120% for 60 s | Approximately 44 A |
| Parameter | Specification |
|---|---|
| Input supply | Three-phase 380–480 V AC, 50/60 Hz |
| Permitted voltage variation | −15% to +10% |
| Maximum output frequency | 400 Hz |
| Control modes | V/f, open-loop vector and open-loop PM vector |
| Cooling | Forced air |
| Operating temperature | −10 to +40 °C |
| Humidity | ≤95% RH, non-condensing |
| Storage temperature | −20 to +60 °C |
Model CIMR-VB4A0038(15) is shown as a Yaskawa CIMR-VB4A0038 drive with front keypad and ventilated enclosure. Match the complete model, physical layout and documented interfaces to the installed component before ordering.
Check complete model suffix, enclosure size, mounting, terminal layout, keypad or control option and cooling arrangement against the installed unit.
Confirm supply voltage and phase, motor power/current, feedback or communication option, braking arrangement and approved parameter set from the exact nameplate and drive schedule.
إمداد موثوق بقطع غيار المصاعد مع خدمة مباشرة من المصنع، وجودة أصلية ودعم يعتمد عليه.
Choose a sales representative to discuss your project.
Loading contacts…