Produktbeschreibung

HL-5391 Adjustable Roller-Lever Limit Switch

A mechanical limit switch with an adjustable metal lever and large roller for position detection and travel control. The metal housing provides a removable cover and accessible screw-terminal connections.

Product Views

HL-5391 large-roller assembly
HL-5391 large-roller assembly
Angled view of the large-roller assembly
Angled view of the large-roller assembly
Horizontal view of the large-roller assembly
Horizontal view of the large-roller assembly
HL series open housing and removable cover
HL series open housing and removable cover
HL series exploded assembly illustration
HL series exploded assembly illustration

Outline Dimensions

HL-5391 outline and mounting dimensions
HL-5391 outline and mounting dimensions

Dimensions in mm. Roller: diameter 50 mm, thickness 6.2 mm. Adjustable arm length: 35-70 mm, 1 mm pitch. Two diameter 5.2 mm through holes. Rod fastening: M4 plate screw; mounting: M6 hexagonal-hole screws. Cover screws: 2 x M3; head-cover screws: 4 x M3. Preserve clearance for roller travel and cable entry.

Product Information

ItemSpecification
ModelHL-5391
Product typeAdjustable roller-lever mechanical limit switch
Contact arrangement1 NO + 1 NC, self-resetting
ActuatorAdjustable metal lever with large roller
HousingMetal enclosure with removable cover
Degree of protectionIP65
Operating speed5 mm/s to 0.5 m/s
Rated frequency50/60 Hz

HL-5391 Operating Characteristics

Operating-characteristic values apply at a lever length of 31.5 mm.

CharacteristicValue
Operating force, OF (maximum)7.35 N
Release force, RF (minimum)0.98 N
Pre-travel, PT (maximum)20 degrees
Over-travel, OT (minimum)50 degrees
Movement differential, MD (maximum)12 degrees

Electrical Load Ratings

Current ratings in amperes. NC = normally closed; NO = normally open. Select the rating for the actual voltage and load type.

Rated voltageResistive NC / NOLamp NC / NOInductive NC / NOMotor NC / NO
125 V AC5 / 51.5 / 0.73 / 32 / 1
250 V AC5 / 51 / 0.553 / 31.5 / 0.8
12 V DC5 / 53 / 34 / 43 / 3
24 V DC5 / 53 / 34 / 43 / 3
125 V DC0.4 / 0.2———
250 V DC0.4 / 0.2———

Electrical Load Conditions

ConditionLimit / basis
Surge current, NC24 A or less
Surge current, NO12 A or less
AC inductive loadPower factor: 0.4 minimum
DC inductive loadTime constant: 7 ms maximum
Lamp-load inrush basis10 times steady-state current
Motor-load inrush basis6 times steady-state current

Operating Environment

CharacteristicValue
Mechanical operating frequency120 operations/minute
Electrical operating frequency30 operations/minute
Initial contact resistance25 milliohms maximum
Ambient temperature-5 to +65 degrees C, without icing
Ambient humidity35-95% RH
Vibration resistance10-55 Hz, 1.5 mm double amplitude

Before Ordering

  • Match the full HL-5391 model, roller dimensions, adjustable lever and mounting arrangement to the installation.
  • Select contact ratings for the actual AC or DC voltage, load type and NO/NC circuit. Do not apply a resistive rating to a motor load.
  • Set the lever position and allow sufficient over-travel without using the switch as a mechanical stop.
  • Confirm the cable entry and sealing arrangement. Isolate power before wiring, adjustment or maintenance.

Frequently Asked Questions

What actuator does the HL-5391 use?

It uses an adjustable metal roller lever with a large roller for mechanical position and travel detection.

What is the contact configuration?

The contact arrangement is one normally open and one normally closed contact (1 NO + 1 NC), with a self-resetting mechanism.

Which current rating should I use?

Use the Electrical Load Ratings table for the actual voltage, load type and contact. Resistive, lamp, inductive and motor loads have different ratings.

How should the lever be set?

Match the lever length and roller position to the operating cam. Allow the required travel and clearance; the operating-characteristic table uses a 31.5 mm lever length.

What should be checked before installation?

Check the mounting dimensions, roller path, cable entry, sealing, electrical load and NO/NC wiring. Installation and maintenance should be performed with the circuit isolated.

Verpackungslösungen

Kartonverpackung
Kartonverpackung
Holzkistenverpackung
Holzkistenverpackung
Palettenverpackung
Palettenverpackung

Fabrik & Fertigung

Werkstatt Werkstatt Lager Produktion

Roboter-Fertigungsstraße

Warum uns wählen?

Zuverlässige Aufzugsteile-Lieferung mit Direktlieferung ab Werk, echter Qualität und verlässlichem Support.

  • 01 100 % Ersatzteilverfügbarkeit
  • 02 Direktlieferung ab Werk
  • 03 Qualitätssicherung
  • 04 One-Stop-Service
  • 05 Zuverlässiger After-Sales-Support

Globale Logistik & Lieferung

Weltweiter Versand

Flexible Lieferoptionen für Kunden in allen Weltmärkten.

Seeverkehr, Luftfracht & Straßentransport

Die Transportmittel können je nach Zielort, Zeitplan und Bestellanforderungen ausgewählt werden.

Sorgfältige Exportverpackung

Die Produkte werden sicher verpackt, um sie während des Transports zu schützen.

Reaktionsfähiger Logistikservice

Unser Team unterstützt die Koordination der Lieferung von der Auftragsbestätigung bis zum After-Sales-Service.

Qualifikationen & Zertifizierungen

✓

Added To Cart Successfully!